The racking files are the input files for the analysis program (LS-DYNA). Each one is the complete wall model: the geometry and mesh of every layer, the material properties, the dowels, laps and bars, the contact between the parts, and the loading. They don't hold the results, those come out when a file is run.
How to open them:
1. As text. They are plain text files, so any text editor (Notepad++ works well) will open them. Not much fun to read, but every input is there and can be checked line by line.
2. As a 3D model. LS-PrePost is the free viewer that goes with LS-DYNA (free download from the Ansys LS-DYNA site). Open the .k file as an LS-DYNA keyword file and you'll see the whole wall. Use the part list to switch layers on and off, so you can hide the skins and the polyiso and look at the dowels, the laps and the core bars on their own. The README in the models folder lists what each part number is.
3. Running them. That takes an LS-DYNA licence and several hours per run on a workstation, so it's really for an engineer checking the work.
What you can learn from them:
The inputs alone show how the wall was built up and what was assumed: the layers, how the panels sit in running bond, the friction values, the dowel detail and the loading. That's useful mostly as the record behind the report, for the engineer of record, an evaluation body or a test lab who wants to check or rerun the analysis.
The results are where the story is. In LS-PrePost you can play the run as an animation and watch the base joint open, the dowels stretch and yield, the exterior skin sliding along its joints, and the cracking spread in the core. The result files are big (about 1.5 GB for a monotonic run and 2.7 GB for a cyclic one), so I didn't include them. If you'd like them, I can share the main monotonic run with 24 in panels and the cyclic run with the 0.30 dowel limit through a download link. Those two show nearly everything in the report.
PRECAST INSULATED CONCRETE WALL SYSTEM, PART 2
Analysis models: in-plane racking, cyclic racking, panel size study
Units in every model: inch, pound-force, second.
Axes: x along the wall, y through the thickness (y = 0 exterior face, y = 12 in interior face), z up.
01_LS-DYNA (LS-DYNA R11, explicit, run on 6 cores)
racking/
racking_monotonic_24in_panels.k virtual ASTM E72 test, top pushed to 2.4 in (2 percent drift) at 4.8 in/s
racking_monotonic_24in_half_speed.k the same at 2.4 in/s (loading rate check)
racking_monotonic_12in_panels.k panel size study
racking_monotonic_36in_panels.k panel size study
racking_cyclic_24in_dowel_limit_0.12.k one full cycle at 0.1, 0.3, 0.6, 1.2 and 1.8 in, dowels break at an
accumulated plastic strain of 0.12
racking_cyclic_24in_dowel_limit_0.30.k the same with the low-cycle fatigue limit of 0.30 and a 10 ms
reversal at each change of direction
wind_panel_size/
wind_suction_12in_panels.k suction on the exterior face raised to 800 psf, 8 ft wall
wind_suction_24in_panels.k
wind_suction_36in_panels.k
Each deck is complete (no include files). Parts: 1 exterior panels, 2 interior panels, 3 polyiso, 4 core,
6 lap strands in the exterior rib, 7 lap strands across the insulation, 8 lap strands in the core,
9 horizontal bars, 11 vertical bars, 13 bond beam (rigid), 14 dowels.
The racking force is the force of the prescribed motion on the bond beam (part 13); the base reactions are the
floor force and the single point constraint forces at the dowel anchors.
02_Mechanical_APDL (Mechanical APDL 2021 R1, batch)
racking_stiffness_and_frequency.inp linear model of the core and interior skin, fixed base, bond beam on
top: racking stiffness under 1,000 lb and first in-plane frequency
with the roof mass, uncracked and with the core at 0.35 of its
modulus
The results of every run are set out in the report, Part 2.
Racking monotonic 34" x 16" half speed
Racking cyclic 24" dowel limit 0.30.k