Yes—in fact, 6 lb of concrete per second is well below a volumetric mixer's normal operating speed, which makes it very easy to sustain, provided you set up continuous material reloading and periodic washouts.
1. The Math: How Fast Is 6 lb/Second?
Standard structural concrete weighs roughly 150 lb per cubic foot (or 4,050 lb per cubic yard):
* 6 lb/second = 360 lb/minute = 21,600 lb/hour
* Divided by 4,050 lb/yd³, that equals ~5.3 cubic yards per hour (or about 0.09 cubic yards per minute).
For comparison, a standard mobile volumetric mixer has a maximum output of 30 to 60+ cubic yards per hour (roughly 35 to 70+ lb per second). Running at 5.3 yd³/hr means the mixer is idling comfortably at roughly 10% to 15% of its rated capacity, which puts very little mechanical strain on the augers, hydraulic motors, or belts.
2. What You Need to Run "All Day Long" Continuously
Because a standard volumetric truck only holds 8 to 12 cubic yards of raw materials on board (which would run out in roughly 90 to 120 minutes at 5.3 yd³/hr), running "all day long" requires three operational adjustments:
* Continuous Top-Loading (Stationary / Plant Mode):
Instead of driving back and forth to reload, you park the volumetric mixer in place (or use a stationary/skid-mounted volumetric unit) and keep its hoppers topped up continuously using overhead silos, conveyor belts, or a front-end loader feeding sand, stone, and bulk cement powder, along with a plumbed water line and bulk admixture totes.
* Low-Speed Auger / Belt Calibration:
At 10%–15% capacity, you must verify that the volumetric unit's Variable Frequency Drive (VFD) or hydraulic flow controls are calibrated for low-end dosing. Some older hydraulic mixers lose metering precision if run too slowly; modern electronic-control volumetric mixers (with digital load cells and closed-loop flow meters) maintain accurate cement-to-aggregate ratios even at low feed rates.
* Scheduled Mixing-Auger Washouts:
Even when running continuously, residual concrete gradually builds up inside the mixing auger tube and along the paddles. To run a full 8- to 12-hour shift without hardened buildup choking the auger or throwing off your mix consistency, operators typically perform a 2-to-3-minute quick water flush every 2 to 3 hours (diverting the rinse water away from the pour).
3. Practical Applications Where This Is Used
Running a volumetric mixer at a slow, steady, continuous output like 6 lb/sec is actually a standard setup in:
* Automated Precast & Block Plants: Feeding a steady, calibrated ribbon of fresh concrete into molds or extruders all day without batch-plant waste.
* 3D Concrete Printing (3DCP): Large-scale construction printers rely on small, continuous volumetric mixers (often dosed at 3 to 10 lb/sec) so the mortar/concrete arrives at the print nozzle with identical rheology and open time every second of the day.
* Continuous Shotcrete / Slope Stabilization: Supplying a steady stream to a shotcrete pump without having high-PSI concrete sitting in a drum losing slump.